RTS-8 Plus Multi-channel Bioreactor with non-invasive real time cell concentration pH and O2 measurement
Product code : BSN.RTS-8PLUS
BSN.RTS-8PLUSMulti-channel Bioreactor with non-invasive real time cell concentration pH and O2 measurement
Via de knop “offerte aanvraag” kan u vrijblijvend contact met ons opnemen voor verdere informatie.
RTS-8 Plus Multi-channel Bioreactor with non-invasive real time cell concentration pH and O2 measurement
Product beschrijving
RTS-8 plus is a personal bioreactor that utilizes patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the single-use falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared, fluorescence and luminescence measurement systems, it is possible to register cell growth kinetics, pH and O2 non-invasively in real time. For pH and O2, innovative single-use sensor spots are used inside the tubes.
Although O2 supply is one of the major issues in the cultivation of aerobic organisms, especially in oxygen limited conditions, adequate methods for real monitoring of dissolved oxygen were missing, and sufficient O2 supply was usually assumed. Innovative non-invasive oxygen sensors integrated in falcon tubes now enable online oxygen monitoring and give new insights into metabolic activities. The pH is one of the major issues in the cultivation of cells, yeast or bacteria. Cultivation vessels which are sensor limited are widely applied in academic and industrial bioprocess development. As adequate methods for real monitoring of pH were not available, cumbersome at-line sampling was used lacking high data density and interfering with growth. Non-invasive real time pH measurement provides new insights into metabolic activity and changes in metabolic pathways.
FEATURES
- Parallel cultivation of 8 tube bioreactors enables to save time and resources for bioprocess optimization
- Individually controlled bioreactor accelerates optimization process
- Possibility to cultivate microaerophilic and obligate anaerobic microorganisms (not strict anaerobic conditions)
- Reverse–Spin® mixing principle enables non-invasive biomass measurement in real time
- Near-infrared optical system makes it possible to register cell growth kinetics
- Free of charge software for storage, demonstration and analysis of data in real time
- Compact design with low profile and small footprint for personal application
- Individual temperature control for bioprocess applications
- Active cooling for rapid temperature control, e.g. for temperature fluctuation experiments
- Task profiling for process automatization
- Cloud data storage to remotely monitor the process of cultivation while at home or using a mobile phone
- Non-invasive O2 and pH measurement allows for accurate monitoring of metabolic activities
ADVANTAGES OF THE SENSOR SPOTS:
- They are small
- Their signal does not depend on the flow rate of the sample
- They can be physically divided from the measuring system which allows a non-invasive measurement
- They can be used in disposables
- Therefore, they are ideally suited for the examination of small sample volumes, for highly parallelized measurements in disposables, and for biotechnological applications
SOFTWARE FEATURES
- Real–Time cell growth logging
- Real-Time pH and O2 measurement and logging
- 3D graphical representation of OD or growth rate over time over unit
- Pause option
- Save/Load option
- Report option: PDF and Excel
- Remote monitoring option (requires internet connection)
- Cycling/Profiling options
- User manual calibration possibility for most cells
TYPICAL APPLICATIONS
- Fermentation real time growth kinetics
- Clone candidate screening
- Protein expression
- Temperature stress and fluctuation experiments
- Media screening and optimization
- Growth characterization
- Inhibition and toxicity tests
- Strain quality control
- Initial bioprocess optimization studies
To fully use RTS-8 plus capabilities, the device must be connected to a PC and RTS-8 plus software. The device cannot be used as a standalone unit.
RTS-8 Plus Multi-channel Bioreactor with non-invasive real time cell concentration pH and O2 measurement
Product specificaties
Packaging Unit
1 Unit
Brand
Biosan
Dimensions (W-D-H)
350×690×300 mm
Display
LED
Light source
LASER
Measurement periodicity per hour
1-60
Measurement range
0-100 OD600
Measurement wavelength (λ)
850 ±15 nm
Nominal operating voltage
230 V, 50 Hz
Sample volume
3–50 ml
Speed control range
50–2700rpm
Temperature control range
+15 °C below ambient ...+60 °C
Temperature setting range
+15°C ...+60°C
Temperature stability
±0.1°C
Weight
20kg
E.coli factory calibration measurement range
0-50 OD600
P.pastoris factory calibration measurement range
0-100 OD600
Achievable user calibration measurementerror (range0.1-3 OD600)
±0.3
Achievable user calibration measurementerror (range3-100 OD600)
≤15%
Sample temperature accuracy (20°C – 37°C)
±1 °C
Tube sockets
8
Power consumption
3.15A/500 W
O2 Sensor
Yes
O2 Sensor range
0-100%
O2 Accuracy
±0.05% O2 at 0.2%, ±0.4% O2 at 20.9%
O2 Temperature range
up to 40°C
O2 sensor response time (T90)
<6 s
O2 Sensor Storage stability
18 months
pH sensor
Yes
pH sensor range
4.0 - 8.5 pH
pH Sensor accuracy
±0.10 pH at pH 7
pH sensor drift
<0.005 pH per day
pH Temperature range
up to 40°C
pH sensor Storage stability
18 months
RTS-8 Plus Multi-channel Bioreactor with non-invasive real time cell concentration pH and O2 measurement
Product documenten